Installation
RE-PLUG is a plug & play device: it requires no wiring or work on the electrical system. Simply plug it into a power outlet in the home or premises supplied by the 2G electronic meter to be monitored.
Before proceeding, carefully read the Safety Precautions. Renua Società Benefit S.r.l. assumes no responsibility for any consequences arising from use of the device that does not comply with the instructions in this manual.
Requirements
- Second-generation electronic meter (2G – Open Meter 2.0). RE-PLUG receives data from the meter via power line communication (PLC), according to the Chain 2 standard, and is not compatible with first-generation meters.
- 230 VAC – 50 Hz power outlet belonging to the electrical system supplied by the 2G meter to be monitored.
- 2.4 GHz Wi-Fi network (IEEE 802.11 b/g/n) with Internet access, available at the installation point.
- Smartphone with Bluetooth and the e-snapp App, with an active e-snapp account, to configure the device and view the data.
If you are unsure about the type of meter installed, contact your distribution system operator or electricity supplier.
Choosing the Installation Point
To ensure reliable communication with the meter and the Wi-Fi network:
- plug the device directly into a wall outlet, avoiding extension cords, multi-socket adapters, or power strips, especially if they include filters or surge protection, which may attenuate the PLC signal;
- choose an outlet with adequate Wi-Fi coverage: for stable operation, a signal level above -70 dBm is recommended;
- install the device indoors, in a dry and protected environment, with a temperature between 0 °C and +40 °C;
- do not cover the device and keep the indicator LEDs visible.
Do not use the device if the enclosure or the plug shows visible damage. Do not install the device outdoors or in damp environments (IP40 degree of protection).
Installation Procedure
- Check that all the requirements are met.
- Plug RE-PLUG into the power outlet selected according to the indications in the previous section.
- Check that the device has switched on using the front LEDs; if necessary, activate it by pressing the button (A) (see Device Description).
- Proceed with Commissioning using the e-snapp App, to connect the device to the Wi-Fi network and to your account, and with Meter Pairing.
Pairing with the Meter (Chain 2)
To receive data from the 2G meter, the device must be paired with the meter of the supply (POD). The request is handled by Renua once the POD code and the supply holder's tax code have been entered in the e-snapp App: see Meter Pairing.